sDAQ Data Acquisition System

Data acquisition

sDAQ Data Acquisition System

The sDAQ data acquisition system is designed for analyzing all necessary parameters of aerodynamics and fluid mechanics.

  • 8 analog inputs
  • Integrated barometer
  • Inputs for PT100, eCTA, 2× ePressure
  • USB

Description

The sDAQ data acquisition system is designed for analyzing all necessary parameters of aerodynamics and fluid mechanics.

The 8-channel data acquisition module with a 16-bit resolution from National Instruments is the central element of the device. The in- and outputs of the device are ready to use for instant connection with the following sensors:

An internal barometric pressure sensor is additionally built in. Thus all essential parameters of subsonic examinations can be tracked and analyzed. All remaining analog inputs are connected to BNC sockets. The PC connection can be established by the built-in USB interface.

A simple data acquisition software is within the scope of delivery. The software provides the configuration of the data acquisition card, reading the measured values, conversion to physical values and the storage of all collected data.

The supplied software is written with LabVIEW 2010 and will be delivered as a stand-alone executable including its source code. Software adaptions according to the user requirements can be easily done based on the supplied software. This requires the NI LabVIEW 2010 software package which is not included.

Features:

  • 1x PT100 temperature sensor
  • 1x eCTA hotwire bridge
  • 2x ePressure differential pressure sensors

sDAQ

Technical data

Data acquisition

8x analogue inputs16 bit, ± 10 V, accuracy ±6 mV, total sampling rate 50 kS/s kHz
2x analogue outputs16 bit, ± 10 V, accuracy ±7 mV, update rate 5 kS/s
8x digital in-/outputsTTL (0-5 V)
1x Counter32 bit / 5 MHz, TTL (0-5 V)

Further internal components

PT100 amplifier0…300° C default, configurable
Barometrical pressure sensor800…1100 hPa
CTA-MainboardSupply eCTA and signal conditioning HD

Connections

1x PT100 temperature sensorBinder Serie 712, 5 pin
1x eCTA hot-wire probeBinder Serie 712, 7 pin
2x ePressure pressure sensorBinder Serie 712, 4 pin
3x analogue inputBNC
2x analogue outputBNC
8x digital in- and outputD-Sub, 9 pin
1x Audio3.5 mm audio jack (30 Ohm)
SupplyBinder Serie 712, 2 pin
USB-interface

Scope of delivery – set

1x sDAQ
1x plug-in power supply 12 V / 1 A
1x Pt100 temperature sensor
1x eCTA hot-wire bridge
2x HWP10/90 hot-wire probe
2x ePressure differential pressure sensor, pressure range at buyer’s option
1x headphone
1x carrying case
SVMdaq software for the recording of the measured values

sDAQ

Accessories & software

Hot-wire bridges compared

The products side by side – and which one fits your measurement task.

More

Online shop

View versions and options in the online shop.

More

More products in this range

Sales & Service

Get in touch

If you have any questions, please contact us by phone or email – we are happy to help!