The 4CTA measurement system is a 4-channel hotwire anemometer.

  • 4 hot-wire channels
  • 0.1–50 m/s
  • 0–5 kHz
  • USB data acquisition, barometer

Description

The 4CTA measurement system is a 4-channel hotwire anemometer. Up to 4 hotwire probes can be operated simultaneously. Due to the extreme short response time, the system is particularly suitable for measurements of instationary flow processes. The system is shipped with calibrated and balanced hotwire probes and is ready to use out of the box.

The integrated USB data aquisition reads the sensor signals and sends them to a connected PC, where the raw data is instantly converted to the appropriate velocities.Furthermore additional sensors like microphones or acceleration sensors can be connected. The integrated 5 kHz  lowpass filter avoids alias-effects. Through the implemented barometer and the front connectable temperature sensor a determination of the air density is possible.

By high pass filtering of the velocity fluctuation signals the flow can be made audiable in real-time, giving an intuitive impression of the flow conditions. Since the ear is the best frequency analyser, the systems represents one of the most efficient methods to analyse aeroacoustic problems.

4CTA

Technical data

General

Velocity range0.1 – 50 m/s in air (calibrated) higher velocities possible, depending on temperature
Frequency resolution0…5 kHz with 3dB lowpass, unfiltered up to 10 kHz is optional

Ambient conditions for hot-wire probes

FluidAir, different non-corrosive gases are possible but must be calibrated separately, no particles, no air pollution
Temperature10…50°C within factory calibration, -10.60°C possible
HumidityNon-condensing

Data acquisition card (option 4CTA-DAQ)

National Instruments USB-6211 (different data acquisition card optional on request)
Analogue inputs16 channels, 16bit, 250kHz total sampling rate
Analogue outputs2 channels, 16bit
Digital in- and outputs4+4 channels, including 1 counter

Further intern components

PT100 amplifier0…300°C default, configurable
Barometric pressure sensor800…1100 hPa
CTA-MainboardSupply and signal conditioning eCTA/eCCT, per hot-wire probe

Power supply

AC110…264 V, 47-63 Hz, 100 W
DC11…18 V, min 4 A, 40 W (Binder 712 2 pin)

Configuration of signal inputs and signal outputs – connections front side

1x PT100 temperature sensorBinder 712, 4 pin
up to 4 hot-wire probesBinder 712, 7 pin
Audio volume and channel selection switch
Earphones3.5 mm audio jack
up to 10 analogue inputsBNC or customized
up to 2 analogue outputsBNC or customized
Digital in- and outputsD-Sub 9 pin or customized

Ambient conditions for electronics

Temperature5…40°C
HumidityNon-condensing

Dimensions

case (H x B x T)134 mm x 234 mm x 333 mm · (19’’ 3HE 42TE)

4CTA

Accessories & software

Hot-wire bridges compared

The products side by side – and which one fits your measurement task.

More

Online shop

View versions and options in the online shop.

More

More products in this range

Sales & Service

Get in touch

If you have any questions, please contact us by phone or email – we are happy to help!